Skip to content
Home / Solutions / Gas Sweetening Optimization / Gas Sweetening Optimiser prototype

Gas Sweetening Optimiser

Treated-gas CO₂ and reboiler duty from three operating variables · response surface, fuzzy logic and ANFIS models trained on 63 Aspen HYSYS runs and tested on runs they never saw, with an optimiser that finds the lowest-energy point on specification

Model
Operating point
Specification, economics and search region
Specification
20 ppm

The thesis design limit is 20 ppm. LNG feed is often held to about 50 ppm.

Economics
$3.00 /MMBtu
8,760 h

Heat basis: 1 kW for a year is 29.9 MMBtu; natural gas emits 53.06 kg CO₂ per MMBtu.

Search region for the optimiser

The design box is where the central composite design tested every combination. Beyond it, only the axial runs were made, one variable at a time.

Show

Click a unit to see what it does · the tags move with the sliders

Material streamEnergy streamSet by you (A, B, C)Predicted resultLayout drawn by AmineOpt from the HYSYS case
Models: AmineOpt (Encyrex) · rotatable central composite design, 20 runs; 40 Latin hypercube and 3 check runs · RSM by hierarchical backward elimination, Mamdani fuzzy inference, ANFIS chosen by repeated 5-fold cross-validationData: Aspen HYSYS simulation of an activated-MDEA acid gas removal unit, MSc research (University of Port Harcourt)